 Current position number signal (PE0 to PE6) Solenoid valve mode 1 [7-point type]

When the PIO pattern is “4” (air-cylinder type), upon completion of positioning the position number (0 to 6)
specified in the applicable move command will be output separately. If push & hold operation is specified, the
corresponding PE signal will turn ON upon detection of successful push & hold operation. However, the
corresponding PE signal will also turn ON even after the load has been missed, so it is not recommended to
specify push & hold operation when missing of the load must be detected.
Simple alarm-code output function is not provided for these signals. If an alarm generates, only the *ALM signal
will turn OFF. Check the details of the alarm code by connecting the PC software or teaching pendant.

Correspondence table of output signals and positions completed

Output signal

Position completed

PE0

Position No. 0

PE1

Position No. 1

PE2

Position No. 2

PE3

Position No. 3

PE4

Position No. 4

PE5

Position No. 5

PE6

Position No. 6


Note) These signals turn OFF when the servo is turned OFF or an emergency stop is actuated. They will return

to the ON status when the servo is turned ON again, provided that the current position is inside the
positioning band with respect to the target position. If the current position is outside the band, the signals
will remain OFF.



(Reference) Output Signal Changes in Each Mode

Mode classification

MOVE

PEND

SV

HEND

PM1 ~

Actuator is stopped with the servo ON after the power was
input

OFF ON ON OFF OFF

Home return is in progress following an input of the home
return signal

ON OFF ON OFF OFF

Home return has completed following an input of the home
return signal

OFF ON ON ON OFF

Actuator is moving in the positioning/push & hold mode

ON

OFF

ON

ON

OFF

Actuator is paused in the positioning/push & hold mode

OFF

OFF

ON

ON

OFF

Positioning has completed in the positioning mode

OFF

ON

ON

ON

ON

Actuator has stopped after contacting the load in the push &
hold mode

OFF ON ON ON ON

Actuator has stopped after missing the load (no load) in the
push & hold mode

OFF OFF ON ON ON

Actuator is stopped with the servo ON in the teaching mode

OFF

ON

ON

Actuator is jogging in the teaching mode

ON

ON

ON

Actuator is being moved by hand with the servo OFF in the
teaching mode

OFF

OFF ON

Servo is OFF after home return

OFF

OFF

OFF

ON

OFF

Emergency stop has been actuated after home return

OFF

OFF

OFF

ON


(Note) Determine whether the actuator has stopped after contacting the load or missing the load from the signal

statuses of MOVE, PEND and PM1 to 8.