3.5 Speed Change during Movement

Example of use in operation) The actuator speed is reduced at a certain point during movement.

The position 150 mm from the home is set as position 1, and the position 200 mm from
the home is set as position 2. The actuator is initially located between the home and
position 1. The actuator is moved to position 2 being the target position, at a travel
speed of 200 mm/sec to position 1 and that of 100 mm/sec from position 1 to position 2.

Method) In this example, the actuator is caused to move to position 1 and to position 2

successively. Before the actuator is stopped at position 1, command position 2 must be
selected/entered and the start signal must be input. To do this, set a wide positioning
band at position 1 and cause the start signal for movement to position 2 to be input
immediately after the completion signal for movement to position 1 is output. (Command
position 2 should be entered while the actuator is moving to position 1.)

Controller








































[11] [9] [5] [2]

[1]

[6]

[8]

[14]

[13] [10] [7] [3]

[12] [4]

[1]

[2]

[3]

[4]

[5]

[6]

[7]

[8]

[9]

[10]

[11]

[12]

[13]

[14]

P


L


C

Signal name

Start

Command position 1

Command position 2

Command position 4

Command position 8

Command position 16

Command position 32

Completed position 1

Completed position 2

Completed position 4

Completed position 8

Completed position 16

Completed position 32

Position complete

Moving

Category

Input















Output

Reference flow

Select/enter command position 1.

Start input ON

Movement to position 1 starts at 200 mm/sec.

Completed position OFF

Position complete output OFF

Moving output ON

Start input OFF

Select/enter command position 2.

Start input ON

Completed position OFF

Position complete output OFF

Start input OFF

Completed position 1 is output.

Moving output OFF

Movement to position 2 completes.

Position complete output turns
ON 10 mm before position 1.

Movement to position 2 starts at 100 mm/sec.

Position complete output turns
ON 0.1 mm before position 2.

Completed position 2 is output.