4.3 Address

Switch


Set an address (0 to 15) as a hexadecimal (0 to F) using the ADRS switch on the front panel of each controller to
define the slave number for the controller.
Assign “0” to the controller nearest the host, and then assign 1, 2, 3, …, E and F to the remaining controllers in
the direction of moving away from the host.
After all addresses have been set, reconnect the power.

Caution: After the setting, be sure to confirm that the addresses are not duplicated.









4.4 Connection

Cables


 Controller link cable

Model: CB-RCB-CTL002














(Reference) Connection diagram for RS232C cross cable

SIO converter end

PC end













Adjust the arrow to a desired
position using a flathead
screwdriver.

D-sub, 9-pin female connector

D-sub, 9-pin female connector

Signal Signal

Controller end

Mini DIN connector

e-Con connector
3-1473562-4
(Housing color: Orange)

Signal Signal

Yellow

Orange

Blue