 Position-command primary filter time constant

Parameter No. 55 defines the delay to be applied when “1 [Primary delay filter]” is set in the
“Acceleration/deceleration mode” field of the position table.
The setting unit is 0.1 mm, while the setting range is 0.0 to 100.00.
The factory setting is “0” [msec].
* The primary delay filter is disabled when “0” is set.

The greater the value set in this parameter, the longer the delay becomes.







 S-motion ratio setting

Parameter No. 56 defines the S-motion level to be applied when “1 [S-motion]” is set in the
“Acceleration/deceleration mode” field of the position table.
The setting unit is %, while the setting range is 0 to 100.
Set to 0% at shipment (S-motion is disabled).
















S-motion has a sine waveform whose single cycle is acceleration time.
Specify the degree of amplitude with parameter No. 56.

Setting of parameter

No. 56 [%]

Degree of amplitude

0 [setting at shipment] No S-motion

(dotted line in the figure below)

100

Amplitude of sine wave x 1

(2-dot dashed line in the figure below)

50

Amplitude of sine wave x 0.5 (1-dot dashed line in the figure below)

10

Amplitude of sine wave x 0.1

(solid line in the figure below)









Speed

Time

Speed

Time

Acceleration time

Amplitude

Setting: 50

Setting: 10

Setting: 100