IAI America SCON-C User Manual

Page 183

Advertising
background image




165

(2) Command pulse mode

User parameter No. 63, “Command-pulse input mode”

Name Symbol Unit Input

range

Default setting

(reference)

Command-pulse

input mode

CPMD

-

0 to 2

1

Set a desired pulse-train input pattern for command pulse input (PP•/PP, NP•/NP).
* Whether to apply the positive logic or negative logic is set in accordance with (3), “Input polarity in the

command pulse mode.”































(3) Input polarity in the command pulse mode

User parameter No. 64, “Command-pulse input mode polarity”

Name Symbol Unit Input

range

Default setting

(reference)

Command-pulse

input mode polarity

POLE

-

0 to 1

0

Setting
Positive logic: 0
Negative logic: 1

Command pulse-train

pattern

Forward Reverse

Neg

a

ti

ve lo

gic

P

osit

ive lo

gic

Forward pulse

train

A forward pulse train indicates motor revolutions in the forward direction, while a
reverse pulse train indicates motor revolutions in the negative direction.

Pulse train

Phase-A/B pulse

train

Phase-A/B x4 pulses with a 90

 phase difference indicate motor revolutions and a

rotating direction.

Pulse train

Sign

Phase-A/B pulse

train

Input

terminal

Reverse pulse

train

Sign

Command pulses indicate motor revolutions, while a command sign indicates a
rotating direction.

Forward pulse

train

Reverse pulse

train

Advertising