9 overview of solenoid valve mode 1 [7-point type – IAI America SCON-C User Manual

Page 108

Advertising
background image




90

2.2.9

Overview of Solenoid Valve mode 1 [7-point Type]

The number of positioning points is kept small, or specifically to seven or less. This type assumes simple
applications where the PLC ladder sequence only requires a simple circuit configuration.
I/O signals provide separate command inputs and movement complete outputs for respective position numbers.
Accordingly, the signal pattern is different from the one in the 64-point positioning type (PIO pattern = 0).

Example) The differences are explained by using an example of moving the actuator to the target position for

position No. 5.

[1] Solenoid valve mode 1 [7-point type]




















* In the Positioning mode [64-point type], a position command input (binary) signal and a start input signal must

be turned ON at staggered timings to initiate movement (refer to the next page). In this type, however, there
is only one input signal that needs to be turned ON.


 Explanation of I/O signals

Signal name

Category

Function explanation

Direct position command 0 (ST0)

Movement command to the target position for position No. 0

Direct position command 1 (ST1)

Movement command to the target position for position No. 1

Direct position command 2 (ST2)

Movement command to the target position for position No. 2

Direct position command 3 (ST3)

Movement command to the target position for position No. 3

Direct position command 4 (ST4)

Movement command to the target position for position No. 4

Direct position command 5 (ST5)

Movement command to the target position for position No. 5

Direct position command 6 (ST6)

Input

Movement command to the target position for position No. 6

Movement complete 0 (PE0)

Indicates that the actuator reached the target position for position No. 0.

Movement complete 1 (PE1)

Indicates that the actuator reached the target position for position No. 1.

Movement complete 2 (PE2)

Indicates that the actuator reached the target position for position No. 2.

Movement complete 3 (PE3)

Indicates that the actuator reached the target position for position No. 3.

Movement complete 4 (PE4)

Indicates that the actuator reached the target position for position No. 4.

Movement complete 5 (PE5)

Indicates that the actuator reached the target position for position No. 5.

Movement complete 6 (PE6)

Output

Indicates that the actuator reached the target position for position No. 6.

Combination of dedicated
movement command input
and complete output

Direct position command 5 input
(ST5)


Movement complete 5 output
(PE5)

Position complete output
(PEND)

No more than 6 msec

Actuator movement

Starting position
of movement

Target position