Appendix

 Home return ends in the middle in a vertical application.

Cause: [1] The load exceeds the rating.

[2] The ball screw is receiving torsional stress due to the affixing method of the actuator, tightening

of bolts only on one side, etc.

[3] The slide resistance of the actuator itself is large.

Action: [1] If [1] is the cause, reduce the load.

[2] Loosen the fixing bolts and check if the slider moves smoothly.

If the slider moves smoothly, review the affixing method and bolt tightening condition.

[3] If the slide resistance of the actuator itself is large, please contact IAI.

 The actuator overshoots when decelerated to a stop.

Cause: The load inertia is high due to an inappropriate balance of load and deceleration.
Action: Decrease the acceleration/deceleration setting.

 The home and target positions sometimes shift.

Cause: [1] The encoder waveform is disturbed by the effect of noise.

[2] In the case of a rod-type actuator, the non-rotation precision increased due to application of

rotating moment to the rod.

Action: [1] Check if the grounding is implemented correctly. Also check for any equipment being a potential

noise source.

[2] The actuator may have to be replaced in some cases. Please contact IAI.

 The actuator moves only a half of, or twice as much as, the specified movement.

Cause: [1] The combination of controller and actuator is wrong.

The lead length of the ball screw varies depending on the actuator type, so a wrong combination
will cause the movement and speed to change.

[2] Factory setting error at IAI

Action: [1] If multiple actuators of different types must be used, confirm using the identification labels, etc.,

that the correct actuator is connected to the controller.

[2] Please contact IAI.

 The SV lamp blinks.

The automatic servo-off mode is active. (This is not an error or fault.)