IAI America SCON-C User Manual

Page 221

Advertising
background image




203

Appendix

4.2 Name and Function of Each Part of the SIO Converter


This is a converter unit conforming to RS485/232C.
















[1] Power/emergency-stop terminal block (TB2)

EMG1, EMG2

Provide a contact output for the emergency-stop switch on the teaching pendant.
EMG1 and EMG2 connect to the emergency-stop switch on the teaching pendant when the
PORT switch is ON, or are shorted when the PORT switch is OFF.
These terminals comprise an interlock with a safety circuit provided by the user.

24V

Positive side of the 24-V power supply (power supply for the teaching pendant and
conversion circuit)

0V

Negative side of the 24-V power supply

FG

FG of the 24-V power supply

(Note) 0V connects to pin 7 (GND) in the controller’s communication connector.


 Connection method

Use a connection cable satisfying the following specifications:

Item Specification

Applicable wire size

Single wire:

0.8 to 1.2 mm / Stranded: AWG size 20 to 18 (end is soldered)

Stripped wire length

10 mm











Used for continuity check

Insert a flathead screwdriver with a bit size of approx. 2.6 mm.

Connection cable

J5

J4

[2] Link-connection terminal block (TB1)

[1] Power/emergency-stop terminal block (TB2)

[6] Monitor LEDs

[3] D-sub, 9-pin connector

[4] Mini DIN, 8-pin connector

[5] PORT switch

[7] e-CON connector

Advertising