<9. OPERATION VIA HART CONFIGURATION TOOL (HART 7)>

9-2

IM 01E30D01-01EN

Configuration Tool, download them from the official

HART programming sites, otherwise, contact the

respective vendors of the Configuration Tool for its

upgrade information.
1. Confirmation of the device revision for AXR

Connect the Configuration Tool to the AXR.

The device revision can be checked as follows.

[Root Menu] → Review → Review4 → Fld dev rev

2. Confirmation of the device revision for the

HART Configuration Tool

(1) Turn on the power of the Configuration Tool

under the standalone condition.

(2) Confirm the installed DD revision in

accordance with the procedure of the

Configuration Tool. Refer to its manual how

to confirm it in detail.

9.3 Interconnection between AXR and HART Configuration Tool

The HART Configuration Tool can interface with the AXR from the control room, the AXR site, or any other

wiring termination point in the loop, provided there is a minimum load resistance of 250 Ω between the

connection and the receiving instrument. To communicate, it must be connected in parallel with the AXR, and

the connections must be non-polarized. Figure 9.3.1 illustrates the wiring connections for a direct interface at

the AXR site. The HART Configuration Tool can be used for remote access from any terminal strip as well.

AXR

F0903.ai

+

SUPPLY

DO

USB

FieldMate

modem

Relaying

terminals

Distributor

Control room

Terminal

board

USB

PC/FieldMate

Figure 9.3.1 Connecting the HART Communicator

WARNING

Be sure to set parameters as “Protect” on the

write protect function after finish of parameter

setting work.

Refer to “Chapter 6 Menu P: Parameter

Protection items” and section “11.3.2” how to use

the write protect function in detail.

IMPORTANT

If the power of flowmeter is turned off within 30

seconds after parameters have been set, these

settings will be canceled. Accordingly, please

keep the power on for at least 30 seconds after

setting parameters.

9.2.2 Device Type Manager (DTM) and

Device Revision

When configure the parameters using FieldMate,

use the DTM (Device Type Manager) referring to

the following table.

MODEL

DTM

Name

Device

Type

Device

Revision

AXR

AXR HART 7

DTM

AXR

(0x3757)

10

The device revision can be checked as follows.

[Root Menu] → Review → Review4 → Fld dev rev