3 iecex, Iecex -4, Warning – Yokogawa ADMAG AXR User Manual

Page 181: 3 iecex warning

Advertising
background image

<14. EXPLOSION PROTECTED TYPE INSTRUMENT>

14-4

IM 01E30D01-01EN

(3) Operation

WARNING

• “OPEN CIRCUIT BEFORE REMOVING

COVERS.”

• “SEALS ALL CONDUITS WITHIN 18

INCHES” in hazardous locations.

• When installed in Division 2, “SEALS NOT

REQUIRED”

• Take care not to generate mechanical

spark when access to the instrument and

peripheral devices in hazardous locations.

(4) Maintenance and Repair

WARNING

The instrument modification or parts replacement

by other than authorized representative of

Yokogawa Electric Corporation is prohibited

and will void the approval of Factory Mutual

Research Corporation.

Non-hazardous

Location

Equipment

HAZARDOUS LOCATIONS DIVISION 1

18" (457mm) Max.

Sealing Fitting

Conduit

F1403.ai

Magnetic Flowmeter

NON-HAZARDOUS

LOCATIONS

35V DC Max.

4-20 mA DC

Signal

Figure 14.2.1 Conduit Wiring

14.3 IECEx

WARNING

Only trained persons use this instrument in

industrial locations.

(1) Technical Data
*AXR025C – AXR200C

Applicable Standard:

IEC 60079-0: 2007, IEC 60079-1: 2007,

IEC 60079-7: 2006, IEC 60079-11: 2006,

IEC 60079-31: 2008

Certificate: IECEx DEK 11.0053
Type of Gas Atmosphere Protection

Type of Protection:

Ex d e ia IIC T6…T4 Gb

Specification of Protection:

Electrode Circuit: Um=250V

Power Supply/Current Output: 42Vdc max., 4 to

20mA, Um=250V

Digital Output: ON; 2Vdc, 120mA max., OFF;

30Vdc max., 4mA, Um=250V

Excitation Circuit: 29 V max.

Enclosure: IP66/IP67

Process Temperature:

Temperature

Class

Maximum Process

Temperature

Minimum Process

Temperature

T6

+70°C (+158°F)

–30°C (–22°F)

T5

+85°C (+185°F)

–30°C (–22°F)

T4

+130°C (+266°F)

–30°C (–22°F)

Ambient Temp.: –30°C to +55°C

(–22°F to +131°F)

Type of Dust Atmosphere Protection

Type of Protection:

Ex tb IIIC T90°C, T110°C, T130°C, Db

Specification of Protection:

Electrode Circuit: Um=250V

Power Supply/Current Output: 42Vdc max., 4 to

20mA, Um=250V

Digital Output: ON; 2Vdc, 120mA max., OFF;

30Vdc max., 4mA, Um=250V

Excitation Circuit: 29 V max.

Enclosure: IP66/IP67

Process Temperature:

Maximum Surface

Temperature

Maximum Process

Temperature

Minimum Process

Temperature

T90°C (+194°F)

+70°C (+158°F)

–30°C (–22°F)

T110°C (+230°F)

+85°C (+185°F)

–30°C (–22°F)

T130°C (+266°F) +130°C (+266°F)

–30°C (–22°F)

Ambient Temp.: –30°C to +55°C

(–22°F to +131°F)

Advertising