<4. WIRING>

4-3

IM 01E30D01-01EN

For working on the electric wire tubes or the flexible

tubes (PF1/2), remove the waterproof gland and

attach them directly to the wiring port.

F0404.ai

Gasket

Washer

Tightening gland

When working on conduit pipes or flexible pipes (PF1/2 only)

Cable

PF1/2

Figure 4.3.2 Waterproof Gland with Union Joint

(Optional code EU)

Plastic gland

Gasket

F0405.ai

Figure 4.3.3 Plastic Gland (Optional code EP)

(3) Conduit Wiring
When wiring the conduits, pass the conduit

through the wiring connection port, and utilize the

waterproof gland to prevent water from flowing in.

Place the conduit pipe on an angle as shown in

Figure 4.3.4. Install a drain valve at the low end of

the vertical pipe, and open the valve regularly.

Drain valve

F0406.ai

Figure 4.3.4 Conduit Wiring