<3. INSTALLATION>

3-10

IM 01E30D01-01EN

Table 3.3.8 Centering Device Identification (AXR Lay length code 2, PFA lining)

Flange

ratings

Size

mm (inch)

JIS

ANSI

DIN

10K

20K

F12

(75M)

150

300

PN10

PN16

PN40

50 (2.0)

B

B

B

F

F

65 (2.5)

B

B

B

G

F

80 (3.0)

B

F

H

F

C

G

100 (4.0)

B

F

H

C

H

F

150 (6.0)

C

D

D

C

E

C

200 (8.0)

C

D

D

D

E

C

C

*: Each centering device is engraved with a character as identification.

Table 3.3.9 Inner Diameters of Grounding Ring,

Outer Diameter for Effective Sealing

Be sure to choose a gasket with an inner and outer

diameter that does not protrude inside the piping.

If the inner diameter of the gasket is too large,

or outer diameter of the gasket is too small, fluid

leakage may result.

Lay length code1 (Flange, Wafer type)

Unit : mm (in.)

Size

Inner diameter of

ground ring[øA]

Outer diameter for

effective sealing[øB]

25 (1.0)

28 (1.10)

53 (2.09)

40 (1.5)

41 (1.61)

71 (2.80)

50 (2.0)

53 (2.09)

84 (3.31)

65 (2.5)

66 (2.60)

103 (4.06)

80 (3.0)

77 (3 .03)

114 (4.49)

100 (4.0)

102 (4.02)

140 (5.51)

150 (6.0)

146.1 (5.75)

190 (7.48)

200 (8.0)

193.6 (7.62)

240 (9.45)

Lay length code2 (Wafer type)

Unit : mm (in.)

Size

Inner diameter of

ground ring[øA]

Outer diameter for

effective sealing[øB]

25 (1.0)

28 (1.10)

53 (2.09)

40 (1.5)

41 (1.61)

71 (2.80)

50 (2.0)

53 (2.09)

84 (3.31)

65 (2.5)

66 (2.60)

103 (4.06)

80 (3.0)

77 (3 .03)

114 (4.49)

100 (4.0)

102 (4.02)

140 (5.51)

150 (6.0)

140.7 (5.54)

190 (7.48)

200 (8.0)

188.9 (7.44)

240 (9.45)

Size of Inner Diameter of Grounding ring and

Outer Diameter for Effective Sealing :

lining

øB øA

AXR Flowtube

Grounding ring

Gasket for

User’s flange

3.3.3 Nominal Diameter 25 mm (1.0 in.) to

200 mm (8.0 in.), Flange Type

IMPORTANT

Use bolts and nuts in compliance with the flange

ratings. Be sure to choose a gasket with inner

and outer diameters that does not protrude

inside the piping (refer to Table 3.3.9). If the

inner diameter of the gasket is too large, or outer

diameter of the gasket is too small, fluid leakage

may result.

(1) Mounting Direction
Mount the flowmeter so that the flow direction of the

fluid to be measured is in line with the direction of

the arrow mark on the flowmeter.

IMPORTANT

If it is impossible to match the direction of

the arrow mark, the direction of the electrical

connection can be changed. Refer to Section

10.1 to do this properly.

In case the fluid being measured flows against

the arrow direction, refer to the parameter

J20:

Flow Direction in this user’s manual.

(2) Tightening Nuts
Tighten the bolts according to the torque values for

the metal piping in Table 3.3.10. For PVC piping,

select an optional code of GA, GC, or GD, use

rubber gaskets and tighten the nuts to the torque

values for the PVC piping in Table 3.3.11.

For permeable fluids (such as nitric acid,

hydrofluoric acid, or sodium hydrate at high

temperatures), tighten the nuts according to the

torque values in Table 3.3.12.