<14. EXPLOSION PROTECTED TYPE INSTRUMENT>

14-1

IM 01E30D01-01EN

14. EXPLOSION PROTECTED TYPE

INSTRUMENT

In this section, further requirements and differences

for explosion proof type instrument are described.

WARNING

Magnetic flowmeters with the model name

AXRC are products which have been

certified as explosion proof type instruments.

Strict limitations are applied to the structures,

installation locations, external wiring work,

maintenance and repairs, etc. of these

instruments. Sufficient care must be taken,

as any violation of the limitations may cause

dangerous situations.

Be sure to read this chapter before handling the

instruments.

For explosion proof type instrument, the

description in this chapter is prior to other

description in this user's manual.

For TIIS flameproof type instruments, be sure

to read “INSTALLATION AND OPERATING

PRECAUTIONS FOR TIIS FLAMEPROOF

EQUIPMENT” at the end of this manual.

WARNING

The terminal box cover and display cover is

locked by special screw. In case of opening

the cover, please use the hexagonal wrench

(nominal size 3).

The covers of explosion proof type products are

locked. Use this hexagonal wrench to open and

close the cover. Before opening the cover, be

sure to check that the power of flowmeter has

been turned off. Once the cover is closed, be

sure to re-lock the product.

Be sure to lock the cover with the special screw

using the hexagonal wrench after tightening the

cover.

14.1 ATEX

WARNING

Only trained persons use this instrument in

industrial locations.

(1) Technical Data
*AXR025C – AXR200C

Applicable Standard:

EN 60079-0: 2009, EN 60079-1: 2007,

EN 60079-7: 2007, EN 60079-11: 2007,

EN 60079-31: 2009

Certificate: DEKRA 11ATEX0144

Type of Gas Atmosphere Protection

Type of Protection:

Group: II

Category: 2G

Ex d e ia IIC T6…T4 Gb

Specification of Protection:

Electrode Circuit: Um=250V

Power Supply/Current Output: 42Vdc max., 4 to

20mA, Um=250V

Digital Output: ON; 2Vdc, 120mA max., OFF;

30Vdc max., 4mA, Um=250V

Excitation Circuit: 29 V max.

Enclosure: IP66/IP67

Process Temperature:

Temperature

Class

Maximum Process

Temperature

Minimum Process

Temperature

T6

+70°C (+158°F)

–30°C (–22°F)

T5

+85°C (+185°F)

–30°C (–22°F)

T4

+130°C (+266°F)

–30°C (–22°F)

Ambient Temp.: –30°C to +55°C

(–22

°F

to +131

°F

)

Type of Dust Atmosphere Protection

Type of Protection:

Group: II

Category: 2D

Ex tb IIIC T90

°C

, T110

°C

, T130

°C

Db

Specification of Protection:

Electrode Circuit: Um=250V

Power Supply/Current Output: 42Vdc max., 4 to

20mA, Um=250V

Advertising