Yokogawa ADMAG AXR User Manual

Page 56

Advertising
background image

<6. PARAMETER DESCRIPTION>

6-8

IM 01E30D01-01EN

(6) Item F (Menu F): Status Functions Setting items
Menu F contains items relevant to multiplex range output and other status Output.

Item

Name

R/W

Data range

Units

Position

of decimal

point

Default value

(*): Indicated item

Description

Display unit

(BRAIN)

Display unit

/BRAIN

F00 Status Function

(STATUS FUNC)

F10 DO Function

(DO FUNCTION)

W

No Function

Pulse Output

Alarm Output

Warning Output

Total Switch

H/L Alarm

Fwd/Rev Rngs

Auto 2 Rngs

Pulse Output

Selects function for the DO

terminal

F11 DO Active Mode

(DO ACT MODE)

W

Closed(On) Act

Open(Off) Act

Closed(On) Act

Selects whether DO terminal

will be set to “On Active” or “Off

Active”.

F20 Forward Span2

(FWD SPAN2)

W

0.00001 to 32000

C40

/C41

0 to 4

1 m/s

Sets flow rate span for forward

No. 2 range

F21 Reverse Span

(REV SPAN)

W

0.00001 to 32000

C40

/C41

0 to 4

1 m/s

Sets flow rate span for reverse

range

F30 Auto Range Hys

(AUTO RNG HYS)

W

0 to 15

%

0

10 %

Sets hysteresis width for

automatic range switching

F31 Bi Direction Hys

(BI DIREC HYS)

W

0 to 8

%

0

2 %

Sets hysteresis width for

forward/reverse switching

F60 —

(SELF CHECK)

R

Good

Error

See “6.5 Alarm Function”.