Standard performance, Standard performance -6, Nstandard performance – Yokogawa ADMAG AXR User Manual

Page 158

Advertising
background image

12-6

IM 01E30D01-01EN

<12. OUTLINE>

n

STANDARD PERFORMANCE

Accuracy:

General-Purpose Use;

Vs: Span setting value (m/s)

Size in mm (in.)

Span in m/s (ft/s)

Accuracy

25 to 100

(1 to 4)

0.3 ≤ Vs < 1

(1 ≤ Vs < 3.3)

±0.25 cm/s

(at indications less than

50% of span)
±(0.4+0.1/Vs)% of rate

(at indications 50% or

more of span)

1 ≤ Vs < 2

(3.3 ≤ Vs < 6.7)

±0.2% of span

(at indications less than

35% of span)
±0.5% of rate

(at indications 35% or

more of span)

2 ≤ Vs ≤ 10

(6.7 ≤ Vs ≤ 33)

±0.16% of span

(at indications less than

30% of span)
±0.5% of rate

(at indications 30% or

more of span)

150 to 200

(6 to 8)

0.3 ≤ Vs < 1

(1 ≤ Vs < 3.3)

±0.30 cm/s

(at indications less than

50% of span)
±(0.3+0.2/Vs)% of rate

(at indications 50% or

more of span)

1 ≤ Vs < 2

(3.3 ≤ Vs < 6.7)

±0.3% of span

(at indications less than

35% of span)
±0.5% of rate

(at indications 35% or

more of span)

2 ≤ Vs ≤ 10

(6.7 ≤ Vs ≤ 33)

±0.16% of span

(at indications less than

30% of span)
±0.5% of rate

(at indications 30% or

more of span)

Explosion proof Type;

Vs: Span setting value (m/s)

Size in mm (in.)

Span in m/s (ft/s)

Accuracy

25 to 100

(1 to 4)

0.3 ≤ Vs < 1

(1 ≤ Vs < 3.3)

±0.30 cm/s

(at indications less than

50% of span)
±(0.3+0.2/Vs)% of rate

(at indications 50% or

more of span)

1 ≤ Vs < 2

(3.3 ≤ Vs < 6.7)

±0.3% of span

(at indications less than

35% of span)
±0.5% of rate

(at indications 35% or

more of span)

2 ≤ Vs ≤ 10

(6.7 ≤ Vs ≤ 33)

±0.16% of span

(at indications less than

30% of span)
±0.5% of rate

(at indications 30% or

more of span)

150 to 200

(6 to 8)

0.3 ≤ Vs < 1

(1 ≤ Vs < 3.3)

±0.50 cm/s

(at indications less than

50% of span)
±(0.5/Vs)% of rate

(at indications 50% or

more of span)

1 ≤ Vs < 2

(3.3 ≤ Vs < 6.7)

±0.45% of span

(at indications less than

30% of span)
±0.25% of span

(at indications from 30%

or more to less than 45%

of span)
0.5% of rate

(at indications 45% or

more of span)

2 ≤ Vs ≤ 10

(6.7 ≤ Vs ≤ 33)

±0.24% of span

(at indications less than

35% of span)
±0.5% of rate

(at indications 35% or

more of span)

The accuracy of a product before shipment is defined

as totalized value at the result of calibration test in our

water actual flow test facility.

Calibrated conditions in our water actual test facility are

as follows:

Fluid temperature:

20 ± 10°C

Ambient temperature:

20 ± 5°C

Length of straight runs: 10 D or more on the up-

stream side; 5 D or more on

the downstream side

Reference conditions:

Similar to BS EN29104

(1993); ISO 9104 (1991)