Flyingsaw, Description of the function blocks – Lenze EVS93xx FlyingSaw User Manual

Page 100

Advertising
background image

FlyingSaw

Description of the function blocks



Prepared Solution Servo PLC / ECSxA 1.1 EN

10-2

Inputs

(Variable type: VAR_INPUT)

Identifier Data

type

Value/meaning

bAbort

BOOL

This input triggers the cancelling of positioning. The input is handled within the application in the
MachineControl. The flying saw is positioned in the initial position during return movement.

FALSE ->TRUE

Cancel the positioning

Profile DINT

Positioning

profile

¾

Data structure; the elements of the structure describe the complete profile

byMotionControlMode DINT

Positioning mode

¾

In the application absolute positioning is performed during movement to the initial position

and constant travel during manual control.

Positioning modes used:

0 Absolute

positioning

2

Continuous constant travel

bMotorInvert BOOL

Entry of the motor mounting direction

FALSE

not inverted

TRUE

inverted

bExternSetValuesEnable BOOL

Switch

to

external setpoints for synchronisation

¾

The external setpoints are looped through 1:1 to the related outputs.

nSpeedOutSaw

INT

Setpoint for the speed for the synchronisation

¾

For this setpoint to be actively switched to the interface, the variable

bExternSetValuesEnable must be set to TRUE.

¾

nSpeedOutSaw -> MCTRL_nNSet_a

dnPosDiffOutSaw DINT

Setpoint for the positional deviation for the synchronisation

¾

For this setpoint to be actively switched to the interface, the variable

bExternSetValuesEnable must be set to TRUE.

¾

dnPosDiffOutSaw -> MCTRL_dnPosSet_p

bHomingMark BOOL

Homing

switch

bMCTRL_bActTPReceived_b BOOL

Input for the MCTRL touch probe

dnMCTRL_dnActIncLastScan DINT

Phase difference in [inc] between latching time and starting time for the task

nMCTRL_nNAct_v

INT

Actual speed for the actual phase integrator

¾

The input is to be connected to the system variable MCTRL_nNAct_v (speed value for
the feedback system) in SB MCTRL.

bDCTRL_bCInh_b

BOOL

Signal for the controller inhibit

¾

The input is to be connected to the system variable DCTRL_bCInh_b in SB DCRTL.

Inputs

(Variable type: VAR_INPUT)

Identifier Data

type

Value/meaning

bMCTRL_bQspOut_b

BOOL

Drive is in quick stop

¾

This input is to be connected to the system variable MCTRL_bQspOut_b in SB
MCTRL.

bReset BOOL

Reset

positioning

Axis AXIS_REF

Machine parameters

¾

Data structure with elements that contain the machine parameters in the internal

measuring system.

¾

Connect this input to a global variable written by the FB L_MCMachineData.

Advertising