FlyingSaw

Description of the function blocks



Prepared Solution Servo PLC / ECSxA 1.1 EN

10-3

Inputs outputs

(Variable type: VAR_IN_OUT)

Identifier Data

type

Value/meaning

bProfileStart

BOOL

Start a positioning

This input signal is automatically reset.

bStartReference BOOL

Start

homing

This input signal is automatically reset

Outputs

(Variable type: VAR_OUTPUT)

Identifier Data

type

Value/meaning

bHomePositionAvailable BOOL

Status signal "Homing done"

¾

The signal is TRUE on successful completion of homing

bHomingBusy

BOOL

Status signal "Homing active"

¾

This signal switches to TRUE when homing is active

bMotionDone BOOL

Status signal "Positioning has been performed"

bPosBusy BOOL

Status signal "Positioning is active"

dnActPosFlyingSaw DINT

Actual phase position of the axis "flying saw"

¾

65536 inc correspond to one revolution on the motor end

nMCTRL_nNSet_a INT

Speed setpoint

¾

This output is to be connected to the system variable MCTRL_nNSet_a in SB MCTRL

dnMCTRL_dnPosSet_p DINT

Positional deviation direct for the position controller

¾

This output is to be connected to the system variable MCTRL_dnPosSet_p in SB

MCTRL. The phase controller must be switched active (MCTRL_bPosOn_b = TRUE)