FlyingSaw

Features of the Prepared Solution



Prepared Solution Servo PLC / ECSxA 1.1 EN

page 2-15

Is this process sequence acceptable for your application?

Process sequence
The process can only be started if the flying saw is in its initial position:

¾

There is no print mark in the sensor's field of view (mark control), currently the

length calculator is not generating a start signal


I


To generate the control signals for the drive system and to evaluate the states, further
components are required in addition to the drive controllers:


Is a higher-level PLC/IPC connected via a bus system, a terminal extension (e.g. Lenze
series EPM terminal extensions) or an HMI connected using the system bus or the
automation interface (AIF)?

?

NO

YES

Add your control concept
using suitable hardware.

Alternatively, if the
programmable variant of the
example solution is used,
control can be achieved by
making an addition to the
program in the x axis drive
controller.

?

NO

YES

Your specific application
can be represented via a
modification of the example
solution.
Please contact your Lenze
representative.

PLC/IPC

HMI

External

terminal

extension

From a functional viewpoint,
the parameterisable variant
of the example solution can
be used for your specific
application.

End