Flyingsaw, Description of the function blocks – Lenze EVS93xx FlyingSaw User Manual

Page 112

Advertising
background image

FlyingSaw

Description of the function blocks



Prepared Solution Servo PLC / ECSxA 1.1 EN

10-14

Inputs

(Variable type: VAR_INPUT)

Identifier Data

type

Value/meaning

bMarkenSync BOOL

Activation of the mark synchronisation.

TRUE

Mark synchronisation active

FALSE

Mark synchronisation not active

dwTi

DWORD

Flying saw acceleration time. The entry is made in the unit [ms]

dwTif

DWORD

Flying saw deceleration time. The entry is made in the unit [ms]

dnGapLengthInc

DINT

Length of the gap. The entry is made in the unit [inc]

bResetError BOOL

In case of an error, the block and as a result all active integrators are reset. The variable must be

included in the application's reset handling.

dnOffset_TP DINT

Distance between the touch probe signal detected and the initial position of the flying saw. The entry is
made in the unit [inc]

Inputs

(Variable type: VAR_OUTPUT)

Identifier Data

type

Value/meaning

bSync_b

BOOL

Status signal "Axis synchronised". The signal is output when the axis is moving in phase and speed
synchronism with the master value.

bStatusGap

BOOL

Status signal "Gap made". The signal is output when a gap has been made in the material.

bFail_b

BOOL

Status signal "Error". The signal is output when an error has been detected during the synchronous
process.

nSpeedOut_a

INT

Actual speed for the actual phase integrator

¾

This input is to be connected to the function block MotionControl.

dnPosDiffOut_p DINT

Positional deviation direct for the position controller

¾

This output is to be connected to the function block MotionControl

dnTir DINT

Actual flying saw acceleration time. The signal is needed for the online calculation of the offset value

and must be connected to the function block OffsetCalculation.