FlyingSaw

Functions



Prepared Solution Servo PLC / ECSxA 1.1 EN

page 3-41

The figure on page 3-31 (word 2 and word 3) shows the factory-set default configuration of the
32-bit application status word. The user can also adapt the configuration of the application
status word using the codes C4012/001 to C4012/032 to suit specific requirements.

It is shown in the following how the application status word can be re-configured bit by bit with
the aid of the parameter setting software GDC:

You'll find the code in the complete code list or in the Short setup => Control/status interface menu

Select the application status word you want to re-configure
Example: To assign bit 6 of the application status word, select the code C4012/007:


Click the code and select the status information that you want to represent using this status bit.
Example: If the signal for the "double length" is to be displayed, select C4012/007 = 17 (Double Length) and
accept using Ok.


If the configuration of further status control bits is to be changed, continue with step 1.


?

YES

⇒ 1

NO

Start

Step 2

Step 1