Parameterise the profiles for the return travel of the flying saw and for the approach of the basic position next :
Set the following codes for setting the parameters:
Parameters for the movement to the initial position:
C3200/000
= Position entry for the movement to the initial position in [units]
C3201/000
= Velocity for the movement to the initial position in [units/s]
C3202/000
= Acceleration for the movement to the initial position in [units/s^2]
C3203/000
= Deceleration for the movement to the initial position in [units/s^2]
Parameters for the return movement profile after sawing
C3300/000
= Velocity in [units/s]
C3301/000
= Acceleration in [units/s^2]
C3302/000
= Deceleration in [units/s^2]
C3303/000
= Jerk time in [s]