Commissioning the "(Flying Saw)"
Prepared Solution Servo PLC / ECSxA 1.1 EN
page 4-61
Select the interface via which you want to control the Prepared Solution :
For this purpose set code C4000/000:
C4000/000
= Control/status interface selection
TIP!
The bit assignment for all 32 control bits of the application control word (word 3 and word 4) can be
changed as required.
Test the correct operation of the application control word (word 3 and word 4) by setting/resetting the control bits
for the functions used in the higher-level PLC and checking the corresponding representation of the control
commands in code C4136/000:
Only run the test when the servo controller is inhibited.