Flyingsaw, Functions, Step 3 – Lenze EVS93xx FlyingSaw User Manual

Page 55

Advertising
background image

FlyingSaw

Functions



Prepared Solution Servo PLC / ECSxA 1.1 EN

page 3-42

Save the modified settings safe against mains failure using C0003/000 = 1.

TIP!

The application status word is displayed using code C4150/000 independent of the operating
mode you select using C4000/000.

Possible settings:

Code

Default

Selection

Comments

C4000

0

0:
1:
2:
3:
4:
5:
6:

Internal control words
CAN 1
CAN 2
CAN 3
AIF1
AIF2
AIF3

Preselection of the control interface:

All three axes can be controlled using the control
interface.

C4012

1
2
3
4
5
6
7
8
9

10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32


0
1
2
3
4
5
6
7
8
9

10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31



0:
1:
2:
3:
4:
5:
6:
7:
8:
9:
10:
11:
12:
13:
14:
15:
16:
17:
18:
19:
20:
21:
22:
23:
24:
25:
26:
27:
28:
29:
30:
31:



Program initialisation complete
Homing done
Axis synchronised signal
Gap made
STATUS standby
STATUS homing active
STATUS inching in positive direction
STATUS inching in negative direction
STATUS top cut is being performed
STATUS automatic selected
STATUS top cut in the ongoing process
STATUS length cut active
STATUS mark cut active
STATUS error detected
Normalisation factor calculated
Homing active
Positioning active
Double length detected
Initial position reached
Mark not detected
Error / TRIP
Warning
Message
QSP active
(not used)
DCTRL ready
Axis in controller inhibit
Axis is in QSP
(not used)
(not used)
(not used)
(not used)

Configuration codes for the status interface:

1:

Status bit 0

2:

Status bit 1

3:

Status bit 2

4:

Status bit 3

5:

Status bit 4

6:

Status bit 5

7:

Status bit 6

8:

Status bit 7

9:

Status bit 8

10:

Status bit 9

11:

Status bit 10

12:

Status bit 11

13:

Status bit 12

14:

Status bit 13

15:

Status bit 14

16:

Status bit 15

17:

Status bit 16

18:

Status bit 17

19:

Status bit 18

20:

Status bit 19

21:

Status bit 20

22:

Status bit 21

23:

Status bit 22

24:

Status bit 23

25:

Status bit 24

26:

Status bit 25

27:

Status bit 26

28:

Status bit 27

29:

Status bit 28

30:

Status bit 29

31:

Status bit 30

32:

Status bit 31


C4150

-

0 ...

{1}

... 4294967295 Status code (display code):

Using the status code the flying saw can be monitored
(with C4000/000 = 0). The individual bits of the status
code can be defined as required using the configuration
codes C4012/001 … 0032. The factory-set bit
assignment is given in code C4012/xxx.

C4152

-

-32767...

{1}

... 32768 Indication of the status word 1 (16-bit integer value):

This code is not predefined in the factory.

End

Step 3

Advertising