FlyingSaw
Dimensioning aspects
Prepared Solution Servo PLC / ECSxA 1.1 EN
page 9-3
Normalisation is calculated as follows:
Parameters for the normalisation:
• Measuring wheel:
measuring wheel constant
(C3005/000) [units/r]
Encoder constant
(C3006/000) [inc/r]
TIP!
Measuring wheel constant: e.g. a measuring wheel with d= 250mm, measuring wheel
constant=250mm*pi=785.4mm/r
• Mechanical system: Feed constant (C1204/000) [units/r]
Gearbox
Gearbox factor numerator (C1202/000)
Gearbox factor denominator (C1203/000)
• Controller:
DFIN master frequency constant (C0425/000)
[inc/r]
TIP!
The normalisation factor is automatically calculated in the application and entered in the codes
C3003/000 and C3004/000.