Dimensioning aspects



Prepared Solution Servo PLC / ECSxA 1.1 EN

page 9-3

Normalisation is calculated as follows:

Parameters for the normalisation:

• Measuring wheel:

measuring wheel constant

(C3005/000) [units/r]

Encoder constant

(C3006/000) [inc/r]

TIP!

Measuring wheel constant: e.g. a measuring wheel with d= 250mm, measuring wheel
constant=250mm*pi=785.4mm/r

• Mechanical system: Feed constant (C1204/000) [units/r]

Gearbox

Gearbox factor numerator (C1202/000)

Gearbox factor denominator (C1203/000)

• Controller:

DFIN master frequency constant (C0425/000)

[inc/r]

TIP!

The normalisation factor is automatically calculated in the application and entered in the codes
C3003/000 and C3004/000.