Commissioning mark-controlled operation



Prepared Solution Servo PLC / ECSxA 1.1 EN

page 6-1

6

Commissioning mark-controlled operation



Attention!

The commissioning of the Prepared Solution described in the following relates to the
parameterisable variant.

Requirements:
ƒ

The parameters for the servo controller for the flying saw axis have been specifically set to suit the specific
case, as described in chapter 4.4.3.

ƒ

The axis is supplied with control voltage using terminals 59 (+24V DC) and 39 (0V) and with power using
terminals L1, L2 and L3.

Initial situation:

• The servo axis is not indicating any error.

• The servo axis is enabled.

• Application control word and application status word have not been specifically set using C4010/0xx and

C4012/0xx.

The axis has been successfully homed

Start GDC and perform a search for drive controllers connected to the system bus. GDC finds the drive
controllers connected. These include the drive controller loaded with the FlyingSaw_SPLC_V0100 project.

Application with ECSxA


Application with ServoPLC

Double-click the controller to be loaded with the FlyingSaw_V0100 application.

Start

Step 1

Start