Commissioning the "(Flying Saw)"



Prepared Solution Servo PLC / ECSxA 1.1 EN

page 4-54

Open the parameters for the configuration of the speed and position feedback system
( (Motor/Feedback systems) Î (Feedback systems)):

Set the following codes:

C0025/000

= Feedback system default setting

C0420/000

= Number of encoder increments on the use of TTL incremental encoders on X8 or

number of periods from Sin/Cos encoders on X8

C0421/000

= Setting for the supply voltage for the feedback system on X8: as a rule the

default value of 5.0V can be retained.

Exception: Absolute value encoders with HIPERFACE interface on X8 require a

higher supply voltage of 8.0V.



Attention!

Applications with position feedback on the load side are not supported by the parameterisable
variant of the Prepared Solution. If it is necessary to use a position feedback system on the load
side, use the programmable variant of the Prepared Solution.