FlyingSaw

Description of the function blocks



Prepared Solution Servo PLC / ECSxA 1.1 EN

10-22

Variable names

Inputs

(Variable type: VAR_INPUT)

Identifier Data

type

Meaning

Selection of the target interface for the status information for the application:

0 Status

code

1 CAN1
2 CAN2
3 CAN3
4 AIF1
5 AIF2

byOutputSource BYTE

6 AIF3

wDCTRL_wStat

WORD

Input for the system status word (system variable

DCTRL_wStat)

wStatW1_a

INT

Definition of the first data word as required (depending on the value on byOutputSource this value is
output to the variable

wInternalStatW1_a, wCAN1_nOutW1_a, wCAN2_nOutW2_a,

wCAN3_nOutW2_a, wAIF1_nOutW1_a, wAIF2_nOutW2_a or wAIF3_nOutW2_a)

bBit00
bBit01

bBit02
bBit03

bBit30
bBit31

BOOL

Definition by bit of the status information (bits 0 to 31):
The individual bits are formed from the internal double status word dwStatWord. Here any input bit

bBit00, bBit01bBit31 can be assigned to any bit in the double status word (dwStatWord.0
dwStatWord.31). The internal index variable abyStatWord[i] (i = 0 … 31) is used for the assignment;

the index i defines the required bit in the double status word (dwStatWord.0dwStatWord.31) and

the value of abyStatWord[i] the required input bit bBit00, bBit01bBit31 for this output bit. The value
range allowed for abyStatWord[i] is 0 … 31.