Variable names, Flyingsaw, Description of the function blocks – Lenze EVS93xx FlyingSaw User Manual

Page 120

Advertising
background image

FlyingSaw

Description of the function blocks



Prepared Solution Servo PLC / ECSxA 1.1 EN

10-22

Variable names

Inputs

(Variable type: VAR_INPUT)

Identifier Data

type

Meaning

Selection of the target interface for the status information for the application:

0 Status

code

1 CAN1
2 CAN2
3 CAN3
4 AIF1
5 AIF2

byOutputSource BYTE

6 AIF3

wDCTRL_wStat

WORD

Input for the system status word (system variable

DCTRL_wStat)

wStatW1_a

INT

Definition of the first data word as required (depending on the value on byOutputSource this value is
output to the variable

wInternalStatW1_a, wCAN1_nOutW1_a, wCAN2_nOutW2_a,

wCAN3_nOutW2_a, wAIF1_nOutW1_a, wAIF2_nOutW2_a or wAIF3_nOutW2_a)

bBit00
bBit01

bBit02
bBit03

…

bBit30
bBit31

BOOL

Definition by bit of the status information (bits 0 to 31):
The individual bits are formed from the internal double status word dwStatWord. Here any input bit

bBit00, bBit01 … bBit31 can be assigned to any bit in the double status word (dwStatWord.0 …
dwStatWord.31). The internal index variable abyStatWord[i] (i = 0 … 31) is used for the assignment;

the index i defines the required bit in the double status word (dwStatWord.0 … dwStatWord.31) and

the value of abyStatWord[i] the required input bit bBit00, bBit01 … bBit31 for this output bit. The value
range allowed for abyStatWord[i] is 0 … 31.