FlyingSaw

Description of the function blocks



Prepared Solution Servo PLC / ECSxA 1.1 EN

10-13

Inputs

(Variable type: VAR_INPUT)

Identifier Data

type

Value/meaning

bSetTPReceived_b BOOL

Input for the touch-probe.
This variable is connected to the system variable DFIN_bTPReceived_b from the system block DFIN.

dnSetTPLastScan DINT

Phase difference between latch point and task start time.

This variable is connected to the system variable DFIN_dnIncLastScan_p

nFrequencyDFINNorm_v INT

Input

for

the normalised master frequency.

This variable is connected to the variable nFrequencyDFIN_v from the function block

MasterFrequency in the library FlyingSawV0100.lib.

nNAct_v

INT

Actual speed for the actual phase integrator.

This variable is connected to the system variable MCTRL_nNAct_v from the system block MCTRL.

Using this variable the saw unit is decelerated after a cut and then positioned at the home position.

The variable is processed logically in the machine sequence and is typically activated by the sawing
action itself.

bStartDeceleration BOOL

FALSE

No deceleration of the saw unit

Start a synchronisation process. The input is connected to the variable bStartSynchronizeprozess

from the function block LengthCalculation in the library FlyingSawV0100.lib.

bStartSynchronize BOOL

FALSE

No start

TDelaySynchronSignal TIME

Delay for the synchronised signal. In this way settling after the synchronising process is taken into

account. The setting is made in the unit [ms].

bAutomatic BOOL

Input information that automatic operation has started.
This input is to be connected to the status automatic.

bStartHeadCut BOOL

Start signal for performing a top cut

bReset BOOL

The integrators for the synchronising process are reset when the variable is set.

bResetAll BOOL

In addition to bReset, when this variable is set the positional deviation is set to zero.

bStartGap BOOL

Start signal for making a gap in the material

nCompensationTrimming

INT

Correction that is added to the setpoint. This correction is used to compensate for an error caused by

the system propagation time.

This input is to be connected to the block LengthCalcualtion nCompensationTrimming

bMotorInvert BOOL

Entry of the motor mounting direction

FALSE

not inverted

TRUE

inverted

bExternSetValuesEnable BOOL

Switch

to

external setpoints for synchronisation

¾

The setpoints from the synchronising process are looped through 1:1 to the related

outputs.

dnOffsetSynchronize DINT

Offset for "synchronous" synchronisation. The value is calculated online by the function block

OffsetCalculation.
This input variable must be connected to the function block OffsetCalculation.

Advertising