page 2-24
The distance between the software limit positions must not be more than 2
31
-1 increments.
Possible settings:
Code
Default
Selection
Comments
C3223
3600.0000 0.0000... {0.0001
[units]}
... 214748.0000 Definition of the positive software limit
Comment: software limits are only active if the home position
for the axis is known and is not set to 0.
C3224
-3600.0000 -214748.0000... {0.0001
[units]}
... 0.0000 Definition of the negative software limit
Comment: software limits are only active if the home position
for the axis is known and is not set to 0.
TIP!
If a 0 is entered for the software limit positions, the software limit positions are deactivated.