(Variable type: VAR_OUTPUT)

Identifier Data

type

Value/meaning

nFrequencyDFIN_v

INT

Output of the frequency for the master value. In the simulation mode the value defined on the input
SimulationMasterFrequency_v is output. Otherwise the master value from the input

MasterFrequency_DFIN_nIn_v. The output variable is also evaluated using the filter time from the
input nFilteringDFIN .

The filtering is only active if the master value is defined using input X9 on the servo axis. The filter time
is not taken into account in the simulation.