Flyingsaw, Description of the function blocks – Lenze EVS93xx FlyingSaw User Manual

Page 107

Advertising
background image

FlyingSaw

Description of the function blocks



Prepared Solution Servo PLC / ECSxA 1.1 EN

10-9

Inputs/outputs

(Variable type: VAR_IN_OUT)

Identifier Data

type

Value/meaning

bHeadCutInProcess

BOOL

Top cut in process.

The length calculator is initialised with actual values by triggering this variable. The variable is

automatically reset in the block.

Outputs

(Variable type: VAR_OUTPUT)

Identifier Data

type

Value/meaning

bStartSynchronizeProcess

BOOL

"Start synchronisation" signal.

The length has been reached and the synchronising process starts.

nCompensationTrimming INT

Correction

that is applied to the setpoint.

In this way an error caused by the system propagation time is compensated.

dnIntegratorValueActual DINT

Output of the actual length.