Flyingsaw, Description of the function blocks – Lenze EVS93xx FlyingSaw User Manual
Page 107
FlyingSaw
Description of the function blocks
Prepared Solution Servo PLC / ECSxA 1.1 EN
10-9
Inputs/outputs
(Variable type: VAR_IN_OUT)
Identifier Data
type
Value/meaning
bHeadCutInProcess
BOOL
Top cut in process.
The length calculator is initialised with actual values by triggering this variable. The variable is
automatically reset in the block.
Outputs
(Variable type: VAR_OUTPUT)
Identifier Data
type
Value/meaning
bStartSynchronizeProcess
BOOL
"Start synchronisation" signal.
The length has been reached and the synchronising process starts.
nCompensationTrimming INT
Correction
that is applied to the setpoint.
In this way an error caused by the system propagation time is compensated.
dnIntegratorValueActual DINT
Output of the actual length.