2 default setting of the servoplc hardware outputs, Flyingsaw, Program extensions/supplements – Lenze EVS93xx FlyingSaw User Manual
Page 90
FlyingSaw
Program extensions/supplements
Prepared Solution Servo PLC / ECSxA 1.1 EN
page 8-2
8.1.2
Default setting of the ServoPLC hardware outputs
Digital outputs (X6)
Terminal Signal
Value/meaning
Controller inhibit
0V Controller is inhibited
A1
DCTRL_bCInh_b
24V Controller is enabled
Home position known
0V No home position known
A2
g_bHomePositionAvailable
24V Home position known
Control of the processing tool, e.g. a saw that starts processing when this signal is switched
0V Axis not synchronised to the master speed
A3
g_bAxisSynchron
24V Axis is synchronised to the master speed
Output of the error state
0V Drive in correct working order
A4
g_bGlobalError
24V Drive has an error
Analog outputs (X6)
Terminal Signal
Value/meaning
62
(not used)
63
(not used)
State bus
Terminal Signal
Value/meaning
ST
(not used)
Master frequency output
(X10)
Terminal Signal
Value/meaning
X10
(not used)