8.1.2

Default setting of the ServoPLC hardware outputs

Digital outputs (X6)

Terminal Signal

Value/meaning

Controller inhibit

0V Controller is inhibited

A1

DCTRL_bCInh_b

24V Controller is enabled

Home position known

0V No home position known

A2

g_bHomePositionAvailable

24V Home position known

Control of the processing tool, e.g. a saw that starts processing when this signal is switched

0V Axis not synchronised to the master speed

A3

g_bAxisSynchron

24V Axis is synchronised to the master speed

Output of the error state

0V Drive in correct working order

A4

g_bGlobalError

24V Drive has an error

Analog outputs (X6)

Terminal Signal

Value/meaning

62

(not used)

63

(not used)

State bus

Terminal Signal

Value/meaning

ST

(not used)

Master frequency output