Flyingsaw, Commissioning the "(flying saw) – Lenze EVS93xx FlyingSaw User Manual
Page 68
![background image](/manuals/566142/68/background.png)
FlyingSaw
Commissioning the "(Flying Saw)"
Prepared Solution Servo PLC / ECSxA 1.1 EN
page 4-55
Now set the machine data for the flying saw
(Short setup Î Settings/flying saw):
Set the following codes:
C3000/000 Setting for the motor mounting position (position polarity)
C1202/000
C1203/000
C1204/000
C1240/000
C1250/000
C3218/000
Gearbox numerator factor
Gearbox denominator factor
Feed constant
Maximum traversing speed
Maximum acceleration
Following error limit (scaled in application units [units])
TIP!
Calculation of the maximum traversing speed (C1240/000).
Caution
: The limit must be set such that it can still be reached with the max. motor speed:
The maximum acceleration figure is determined from the maximum motor torque
and the moment of inertia to be accelerated:
An initial reference value can be defined using the maximum speed set in C1240.
If it is ensured the machine can accelerate to maximum speed in a time defined by you,
for C1250 the following is found:
Step 4