Flyingsaw, Commissioning the "(flying saw) – Lenze EVS93xx FlyingSaw User Manual

Page 68

Advertising
background image

FlyingSaw

Commissioning the "(Flying Saw)"



Prepared Solution Servo PLC / ECSxA 1.1 EN

page 4-55

Now set the machine data for the flying saw
(Short setup Î Settings/flying saw):


Set the following codes:

C3000/000 Setting for the motor mounting position (position polarity)

C1202/000
C1203/000
C1204/000
C1240/000
C1250/000
C3218/000

Gearbox numerator factor
Gearbox denominator factor
Feed constant
Maximum traversing speed
Maximum acceleration
Following error limit (scaled in application units [units])

TIP!

Calculation of the maximum traversing speed (C1240/000).
Caution

: The limit must be set such that it can still be reached with the max. motor speed:

The maximum acceleration figure is determined from the maximum motor torque
and the moment of inertia to be accelerated:

An initial reference value can be defined using the maximum speed set in C1240.
If it is ensured the machine can accelerate to maximum speed in a time defined by you,
for C1250 the following is found:

Step 4