Chapter 7: testing and maintenance, General, Checking without test equipment – Rockwell Automation 825 Smart Motor Manager User Manual User Manual

Page 127: Functional check with the test button, Chapter 7 — testing and maintenance, Functional check with the t, Testing and maintenance, Chapter

Advertising
background image

Publication 825-UM001B-EN-P January 2001

Chapter

7



Testing and Maintenance

General

The correct functioning of the Smart Motor Manager can be checked by several methods,
depending on the requirements:

With the Test button

With the test condition set

With a single- or 3-phase current source

A test may be beneficial:

During commissioning

Following an interruption in operation

Following overhauls

Following reconstruction of the installation

After a test is conducted, the display provides information on the running time of the Smart
Motor Manager and the motor, the number of operations performed by the motor, the
contactor, etc. From this information, necessary maintenance and installation replacements
can be derived.

Checking without Test Equipment

Functional Check with the Test Button

With the motor at standstill, the thermal protection, all alarms, trips, and tripping times can be
checked with the aid of the Test button. Page

3-9

for the specific procedures.