Error Diagnosis and Troubleshooting 8-9

Publication 825-UM001B-EN-P January 2001

Other Trips

Indication

LCD: Does not display the type of the trip (LCD active)

Red LED: ON

Cause for this Condition:

If the tripped protection function has been switched “OFF”, before the trip has been reset,
then the trip can not be reset the normal way.

How to Reset

Go to RECORDED VALUES mode

Go to “CAUSE LAST TRIP” e.g., “ASYMMETRY TRIP”

Go to SET VALUES mode

Go to tripped Protection Function e.g., “ASYMMETRY TRIP”

Switch Protection Function on e.g., “ASYMMETRY TRIP” “ON”

Reset Trip: Red LED goes off

Switch Protection Function off, if not required