Table 3.z, Sensor measuring circuit specifications – Rockwell Automation 825 Smart Motor Manager User Manual User Manual

Page 80

Advertising
background image

3-47 Functions

Publication 825-UM001B-EN-P January 2001

Table 3.Z Sensor Measuring Circuit Specifications

➊ Twisted lead: 25 times twisted per m

Screened lead: Screen connected to T2

Function

Factory setting

Off

Sensor Measuring Circuit

Max. resistance of the PTC chain when cold

1.5 k

Max. number of sensors as per IEC 34-11-2

6

Pickup value at

δ

A

= –5…+60

°

C

3.3 k

± 0.3 k

Dropout value at

δ

A

= –5…+60

°

C

1.8 k

± 0.3 k

Delay on pickup

800 ms ± 200 ms

Pickup value when short-circuit in sensors circuit
at

δ

A

= –5…+60

°

C

15

Measuring voltage as per IEC 34-11-2

< 2.5V DC

Measuring Lead

Minimum cross-section

[mm

2

]

[AWG No.]

0.5

20

0.75

18

1.0

17

1.5

16

2.5

14

Maximum length

[m]

[ft]

200
656

300
984

400

1 312

600

1 968

1 000
3 280

Method of installation ➊

up to 100 m (328 ft) twisted, unscreened

Advertising