8-6 Error Diagnosis and Troubleshooting

Publication 825-UM001B-EN-P January 2001

Table 8.A Possible Causes and Actions (Continued)

LCD

Designation

Possible Causes

Actions

Earth (ground)

fault

(Holmgreen/
residual) trip

Earth (ground) fault motor
winding or cable

Repair damage.

Trip when running:

Primary current transformer
wrongly wired

Primary current transformer
saturated

High proportion of third
harmonic in star-delta

Correct wiring.

Raise pickup threshold.

Raise pickup threshold to 50%
or more.

Earth (ground)

fault warning

with core

balance

transformer

Earth (ground)

fault trip

with core

balance

transformer

Trip during start: Primary and
core balance transformer wired
incorrectly

Correct the wiring (core balance
transformer may only surround
the three motor leads).

Long motor cable

Raise pickup threshold.

Earth (ground) fault in motor
winding or cable due to:

Moisture

Dirt

Mechanical damage

Eliminate cause.

Short-circuit

trip

Short-circuit or earth (ground)
fault in motor winding or cable

Repair damage.

Trip when motor is switched on,
due to inrush current

Increase trip delay to > 0.1 s.

Pickup threshold is <

,

A

Set pickup threshold to >

,

A

.

Underload

warning

Underload trip

Underwater pump running dry

Eliminate cause, lower pickup
threshold if necessary or increase
trip delay.

Faulty fan blades

If tripping takes place too soon
after starting, increase the start
delay.

Torn conveyor belt

Eliminate cause.

Broken transmission elements
Pumping against a closed valve
Current setting

,

e

too high

Set correct value.

Max. number

of starts/h

reached

Maximum number of starts has
been exceeded.

Wait until another start is
permissible. Release will be
automatic.
If another start is permissible,
increase number of start/hour by
“1” and start again.

Start in max.
starting time

not possible

Overloaded

Reduce load or raise max. starting
time to permissible value.

Transport material jammed

Eliminate cause.

Viscous material

Raise max. starting time to
permissible value.

EF HOLMG TRIP

EF C WARNING

EF CORE TRIP

SHORT CIRC PROT

UL WARNING

UNDERLOAD TRIP

START INHIB TRIP

START CONT TRIP