Value name (units)

Default

value

Description

Location in pre-RSBizWare 9.0

software

LogLocation CalcThreadFault
Metrics (On or Off)

Off

Turns the application-specific informational
and debug-level logging on or off for fault
metric calculation messages in the

Calculator thread.

The LogLocation registry value, with bit 200
set in the hexadecimal bitmask.

LogLocation CalcThreadMachine
State (On or Off)

Off

Turns the application-specific informational
and debug-level logging on or off for

machine state calculation messages in the
Calculator thread.

The LogLocation registry value, with bit 400
set in the hexadecimal bitmask.

LogLocation ServerRequests (On
or Off)

Off

Turns the application-specific informational
and debug-level logging on or off for server
request handling.

The LogLocation registry value, with bit
1000 set in the hexadecimal bitmask.

LogLocation DataProcessing
Queue (On or Off)

Off

Turns the application-specific informational
and debug-level logging on or off for data
processing queue handling.

The LogLocation registry value, with bit
4000 set in the hexadecimal bitmask.

LogLocation Memory

Management (On or Off)

Off

Turns the application-specific informational

and debug-level logging on or off for
messages in the Memory Management

thread.

This value did not exist in versions of the

software prior to RSBizWare 9.0.

StartupRSLAgeLimit (Minutes) 10

Discards the first RSL file processed if it is as
many minutes older than the current time

as specified in the value.

The RSL Check Time Duration registry value.

InitializeFromSingle Timestamp
(1 or 0)

1

1 - Initialize data collection from a single
timestamp provided by the heart beat
transactions and discard data that is older

than the initializing time.
0 - Use all data regardless of the timestamp.

The Init Values Type registry value.

ShiftRecursion Duration

(Minutes)

60

The amount of time used to recursively

search for the start of the current shift.

The Shift Recurse Gap registry value.

Summarization Overlap
(Seconds)

2

Summarization criteria changes that occur
within this amount of time will be
considered a single change and will not

generate multiple summarizations.

The Summarization Gap registry value.

DataQueueSleep Threshold (# of
Data Queue Items)

100

The number of items waiting to be
processed. If the number is exceeded, the

Calculator thread remains awake for a small
amount of time not to consume all the CPU

time. This is the number of items indicating
that the server is busy enough so that it does

The Sleep Threshold registry value.

218