Application notes for FactoryTalk Transaction Manager Appendix D

2. Using the RSLinx Data Points dialog box, define the

following:

Item

Description

Item Address

SystemTimeINT[0],L6

Datapoint Name

Either type in a unique name or let the system name the
point for you automatically.

Topic

Use Default or the specific topic you have defined in RSLinx

Data Type

PLC Timestamp

Elements

6

3. Create a transaction and bind the FactoryTalk Transaction

Manager data point to a date/time field in the database (the
actual data type may be called TIMESTAMP or DATE or

DATETIME, depending on the database used).

If you are using a configuration that uses online edits, you can only

distribute certain parts of the application across multiple computers.
In a configuration that uses online edits via a COM+ enterprise
connector, there are three main parts:

• Transaction Control Manager (TCM).
• The COM+ enterprise connector.
• The .DLL file written by the user.

If you wish to put the TCM and the COM+ enterprise connector
on separate computers, then the user-written .DLL must be located
on the same computer as the COM+ enterprise connector. If you

have the TCM and the COM+ enterprise connector on the same
computer, then the user-written .DLL can be located on a different
computer. You cannot, however, locate the TCM, COM+
enterprise connector and the user-written .DLL on different
computers.

The COM+ network access is disabled by default on Windows 2003
Standard Server computers. For details on how to enable it, see

Special considerations for a
distributed Microsoft COM+
application

Rockwell Automation Publication BZWARE-IN001M-EN-P-June 2014