Appendix D Application notes for FactoryTalk Transaction Manager

"Enabling network COM+ access for COM+ connectors in
FactoryTalk Transaction Manager (page 284)".

COM+ network access is disabled by default on Windows 2003

Server Standard Edition Server platforms. On these platforms,
COM+ can be used only locally by default.

To enable the network COM+ access for COM+ connectors in
FactoryTalk Transaction Manager:

1. Open Control Panel.
2. In Control Panel, click Add or Remove Programs.
3. Click Add/Remove Windows Components.
4. Click Application Server, and then click Details.
5. Select the check box next to Enable network COM+ access,

and then click OK.

6. Click Next, and then click Finish.

To configure the Oracle 10g R2 Instant Client:

1. Install the Oracle 10g R2 Instant Client with default settings.
2. Install the Oracle patch for defect #4951251.

NOTE

If you do not install the Oracle patch for defect #4951251,

FactoryTalk Transaction Manager will not find the Oracle SQLNet
connections defined in the tnsnames.ora file.

3. Open the following directory:

c:\oracle\product\10.2.0\Client_1

4. In the Client_1 folder, create a new folder,

Network

.

5. In the Network folder, create a new folder,

Admin

.

6. From the database server system, copy the tnsnames.ora file to

the Admin folder.

Enabling network COM+
access for COM+ connectors
in FactoryTalk Transaction

Manager

Configuring the Oracle 10g
Instant Client for FactoryTalk
Transaction Manager

284

Rockwell Automation Publication BZWARE-IN001M-EN-P-June 2014