Appendix D Application notes for FactoryTalk Transaction Manager

If you select this option:

And the device is off at startup,

then the transaction:

And the device is on at startup, then

the transaction:

Substitute Previous Value

Fails because a previous value for
substitution did not exist.
For corrective action information, see the

possible solution section for error 33175.

Uses the previous substitute value and the
quality is set to 1.

Use Bad Quality

Uses the bad quality value provided by the
data server.

Uses the bad quality value provided by the
data server.

Use Substitution for Bad Quality

Uses the substitution for bad quality value
provided by the data server.

Uses the substitution for bad quality value
provided by the data server.

Use Previous Substitution for Bad Quality

Uses the previous substitution for bad
quality value provided by the data server.

Uses the previous substitution for bad
quality value provided by the data server.

In RSSql v8.00.00 and FactoryTalk Transaction Manager v10.20 or
later, you can no longer enter IP addresses in the Add

Configuration Server or FactoryTalk Transaction Manager
Configuration
dialog boxes. If you have been using IP addresses on

these dialog boxes in RSSql v7.50.00 and earlier, you must change
your configurations to use host names.

To resolve an IP address in a Windows Domain:

If you are working in a Windows Domain, perform the following
steps:

1. In FactoryTalk Transaction Manager, replace the IP address

with the appropriate host name.

2. At the command prompt, type:

ping <host name for the computer>

For example:

ping FactoryTalk Transaction

ManagerServerA

3. View the output of this operation and verify that the IP

address that is displayed matches the IP address that you used
in your previous FactoryTalk Transaction Manager
configuration.

Resolving IP address to host
name issues

290

Rockwell Automation Publication BZWARE-IN001M-EN-P-June 2014