Methods of Protection

The following techniques are rated by methods of protection.

Temperature Category

The temperature category defines the maximum surface temperature of the
device. Ratings are given with reference to 40

o

C ambient unless otherwise

stated.

Technique

Symbol for Protection Method

Permitted Zone

Permitted Division

Zone

Division

IEC

CENELEC

NEC

CEC

Oil Immersion

Ex o

EEx o

AEx o

Ex o

1 and 2

*

Pressurization

Ex p

EEx p

AEx p

Ex p

Type X, Y, Z

1 and 2

1 (X, Y) and 2 (Z)

Powder Filling

Ex q

EEx q

AEx q

Ex q

1 and 2

*

Flameproof

Ex d

EEx d

AEx d

Ex d

1 and 2

Explosionproof

XP

1 and 2

Increased Safety

Ex e

EEx e

AEx e

Ex e

1 and 2

*

Intrinsic Safety

Dual Fault
Single Fault

Ex ia
Ex ib

EEx ia
EEx ib

AEx ia
AEx ib

Ex ia
Ex ib

IS

0, 1, and 2

1 and 2

1 and 2

Non-Incendive

Limited Energy
Non-Sparking
Enclosed Break
Restricted Breathing
Simplified Pressurization

Ex nL

Ex nV

Ex nW

Ex nR
Ex nP

EEx nL

EEx nV

EEx nW

EEx nR

EEx nP

AEx nL

AEx nV

AEx nW

AEx nR
AEx nP

Ex nL

Ex nV

Ex nW

Ex nR
Ex nP

NI

2

2

Encapsulation

Ex m

EEx m

Aex m

Ex m

1 and 2

*

*

These protection methods are not recognized in the Division method. However, they may be suitable for some North American Division applications.

T1

450

o

C (842

o

F)

T3A

180

o

C (356

o

F)

T2

300

o

C (572

o

F)

T3B

165

o

C (329

o

F)

T2A

280

o

C (536

o

F)

T3C

160

o

C (320

o

F)

T2B

260

o

C (500

o

F)

T4

135

o

C (275

o

F)

T2C

230

o

C (446

o

F)

T4A

120

o

C (248

o

F)

T2D

215

o

C (419

o

F)

T5

100

o

C (212

o

F)

T3

200

o

C (392

o

F)

T6

85

o

C (185

o

F)

The additional temperature categories highlighted above are for North America only.