Chapter 13, 1797-ij2 flex ex frequency input module, General information – Rockwell Automation 1797-XXX FLEX Ex System Certification Reference Manual User Manual

Page 73: Module installation, Inputs

Advertising
background image

1

Publication 1797-6.5.6 - June 2005

Chapter

13

1797-IJ2 FLEX Ex Frequency Input Module

General Information

Modules must be used with a 1797-TB3 or -TB3S intrinsically safe terminal
base unit.

Module Installation

Rotate keyswitch on terminal base unit clockwise to position 1 as required for
this type of module. Do not change the position of the keyswitch after
wiring the terminal base unit.

Inputs

The frequency input module has 2 input channels. Each input can accept
inputs from magnetic pickups or proximity probes. Each input channel has 2
input selections: frequency input or gate input. Do not apply any
non-intrinsically safe signals to this module.

The channels in this module are electrically connected to each other.

When using an intrinsically safe electrical apparatus according to EN50020,
the European directives and regulations must be followed.

IMPORTANT

When interconnecting several lines, you must consider the
total accumulated power and check for intrinsic safety.