1797-IJ2 FLEX Ex Frequency Input Module 13-5

Channel 0 Gate Input

Field devices may only be connected to the terminal of one of the three
following circuits. The terminals of the remaining two circuits must not be
connected.

Channel 1 Gate Input

Field devices may only be connected to the terminals of one of the three
circuits. The terminals of the remaining two circuits must not be connected.

Namur/Con
tact
(terminals
23-24)

Protection

Group

Allowed
Capacitance

Allowed
Inductance

L

o

R

o

Ratio

U

o

= 14.7V

I

o

= 15mA

P

o

= 30mW

EEx ia

IIB

3.86

µF

300mH

2.6mH/

IIC

620nF

80mH

0.65mH/

Magnetic
500mV
(terminals
22-20)

Protection

Group

Allowed
Capacitance

Allowed
Inductance

L

o

R

o

Ratio

U

o

= 14.7V

I

o

= 10mA

P

o

= 18mW

EEx ia

IIB

3.86

µF

600mH

4.15mH/

IIC

620nF

150mH

1.03mH/

Magnetic
50mV
(terminals
22-20,
23-21)

Protection

Group

Allowed
Capacitance

Allowed
Inductance

L

o

R

o

Ratio

U

o

= 14.7V

I

o

= 10mA

P

o

= 18mW

EEx ia

IIB

3.86

µF

600mH

4.15mH/

IIC

620nF

150mH

1.03mH/

Namur/Con
tact
(terminals
26-25)

Protection

Group

Allowed
Capacitance

Allowed
Inductance

L

o

R

o

Ratio

U

o

= 14.7V

I

o

= 15mA

P

o

= 30mW

EEx ia

IIB

3.86

µF

300mH

2.6mH/

IIC

620nF

80mH

0.65mH/

Advertising