Publication 1797-6.5.6 - June 2005

6-2 1797-OB4D FLEX Ex 24V dc Non-Isolated Source 4 Output Module

Intrinsically Safe
Specifications

For a full list of specifications, refer to FLEX Ex 24V dc Non-Isolated Source
4 Output Module Installation Instructions, publication 1797-5.6.

CE/CENELEC I/O Entity
Parameters

Signal output (+ to -) for ch 0 to ch 3 (terminals: 0-1; 4-5; 8-9; 12-13)

ATTENTION

Do not use any unused terminals on this terminal base unit.
Using these terminals as supporting terminals can result in
damage to the module and/or unintended operation of
your system.

Output (intrinsically safe)

(16 position male/female flexbus
connector)

U

i

< 5.8V

I

i

< 400mA

Li = Negligible
Ci = 1.35

µ

F

Power Supply

(+V, -V Intrinsically Safe)

U

i

< 9.5V dc

I

i

< 1A

L

i

= Negligible

C

i

< Negligible

Operating Temperature

-20 to +70

o

C (-4 to +158

o

F)

Agency Certification

II (1) 2G EEx ia/ib IIB/IIC T4
II (1D) (2D)

Certificates

DMT 98 ATEX E 040 X

Protection

Group

Allowed
Capacitance

Allowed
Inductance

1797-OB4D
U

o

= 27.4V

I

o

= 110mA

EEx ia

IIB

677nF

8mH

IIC

87nF

2mH

If
concentrated
capacitance
and/or
inductance
are available,
use the
following
values.

EEx ia

IIB

150nF

5mH

IIC

30nF

2mH