Adding and Removing Power Supplies

9–5

Publication 6180-6.0

ATTENTION: Make sure the flow director is properly
positioned between the power supply and base of the
processor socket. Failure to correctly install the flow
director may result in excessive temperatures which can
damage the processor.

3. Make sure the flow director is positioned correctly.

On Pentium systems, the flow director is directed at the base of
the processor socket. The flow director tabs are inserted into the
power supply below the fan. The free end of the flow director is
positioned against the base of the processor socket.

On Pentium II and Pentium III systems, the flow director is
attached to the power supply. The flow director surrounds the
slot 1 processor module and draws air away.

Figure 9- 3

4. Install the power supply filter, if applicable (Pentium II and DC

powered systems do not require power supply filters).

5. Install the back panel.