Panel mounting (with studs) – Rockwell Automation 6180 Industrial Computers User Manual

Page 46

Advertising
background image

2–10 Installation

Publication 6180-6.0

To install the 6180 Computer in a panel using 18 mounting studs:

ATTENTION: Disconnect all electrical power from the
panel before making cutout.

Make sure the area around the panel cutout is clear.

Take precautions so that metal cuttings do not enter any
components that are already installed in the panel.

Failure to follow these warnings may result in personal
injury or damage to the panel components.

To install the 6180 Computer in a panel using mounting studs:

1. Cut an opening in the panel using the panel cutout dimensions

provided on page 28. Carefully drill eighteen 1/4 inch (6.35 mm)
holes for studs as indicated.

2. The 18 mounting studs are factory installed. In the event studs were

removed for clip mounting, you can re–install studs using a 1/8 inch
socket on the end of the stud. Turn stud clockwise to tighten to
approximately 10 inch pounds (1.1 N•m).

Figure 2- 7

ATTENTION: Be careful not to damage the sealing
gasket when installing or removing studs. A damaged
seal may result in damage to the 6180 Computer and
other panel components due to a leaking seal.

Panel Mounting

(with Studs)

Mounting Studs

(Qty 18)

Bezel

Gasket

Spacer

Self-Locking Nuts

Panel or Enclosure

Advertising