Rockwell Automation 6180 Industrial Computers User Manual

Page 175

Advertising
background image

Specifications

1–3

Publication 6180-6.0

Shock and Vibration

Impulse Shock
operating
non–operating

15G (1/2 sine, 11 msec)
30G (1/2 sine, 11 msec)

Vibration Operating

Swept sine input,
0.006 inch displacement 10–57 Hz
1.0g acceleration 57–150 Hz

Agency Certifications

UL/cUL 508/1950

FCC class A

CE marked for all applicable directives

EMC EN 50081–2/82–2
LVD EN 60950

The following table provides operating and technical specifications of
the available power supplies:

Phase 1 and 2

160 Watt Supply

210 Watt Supply

Input Voltage

100 to 120V AC RMS

100 to 120 AC RMS

200 to 240V AC RMS

200 to 240V AC RMS

Min. and Max. Voltages

1

90 to 135V AC RMS
180 to 265V AC RMS

85 to 135V AC RMS
170 to 265V AC RMS

Input Voltage Selection

Input Selector Switch

Automatic

Input Frequency

47 to 63 Hz

47 to 63 Hz

Output Power at 50°C

160 Watts

210 Watts

Operating Temperature

10 to 50°C (40 to 122°F)

0 to 50°C (32 to 122°F)

Shock 15G

30G Non–Operating

15G Operating
30G Non–Operating

Vibration

1G Operating, 2G Non-
operating

1G Operating, 2G Non-
operating

Thermal Shutdown

No

Yes

Voltage Holdup Time

17msec at 115V AC
and full power

20msec at 85V AC
and full power

1

These voltages are operating limits not recommended operating voltages. Refer to Input

Voltage specifications for recommended supply voltage ranges.

Phase 3

180 Watt Supply for Slot 1 CPUs

Input Voltage

100 to 120 AC RMS

200 to 240V AC RMS

Min. and Max. Voltages

1

85 to 135V AC RMS
170 to 265V AC RMS

Input Voltage Selection

Automatic

Input Frequency

47 to 63 Hz

Advertising