DS0 Monitor Details Screen (5160 Only)

To access the DS0 Monitor Details Screen (Figure 4.21), click on “TDM” in
the <Type> column on the Service Table screen. This screen lets you
configure what are considered high and low DS0 utilization parameters, and
will report alarms if the monitored statistics rise above or fall below those
specified settings. This helps determine customer load patterns so that channel
bandwidth can be reallocated as necessary.

Figure 4.21

DS0 Monitor Details Screen

Number of DS0s

Number of active DS0s (0

24) assigned on a per-service basis.

Alarm Reset Timer

(sec)

Number of seconds that an alarm condition must not be present before an
alarm is reset. Zero (0) indicates the Alarm Reset Timer is disabled.

Values: 0

900

Default: 30

High Utilization %

Lets you configure as a percent what is considered high utilization.

Values: 1

100

Default: 100

High Threshold (sec)

Lets you configure a high-utilization threshold (in seconds), above which an
alarm will report.

Values: 0

900

Default: 0 (Disabled)

End of Day Low

Utilization %

Lets you configure as a percent what is considered low utilization at the end
of the day. If the utilization is below this level when the day ends, an alarm
reports.

Values: 0

100

Default: 0 (Disabled)

DS0 Status and Alarm Table

Each second, the TDM services will count the number of active DS0s and
update their statistics. You must refresh your screen to view the updated