Verilink WANsuite 5130 (34-00298.L) Product Manual User Manual

Page 261

Advertising
background image

S N M P A g e n t

B-9

ipadt1e1LOSSAlarmDeclared

25012

This trap is sent out when a Loss
of Signal Seconds alarm is
declared.

t1e1LOSSCount

ipadt1e1UASAlarmDeclared

25013

This trap is sent out when an
Unavailable Seconds alarm is
declared.

t1e1UASCount

ipadt1e1CSSAlarmDeclared

25014

This trap is sent out when a
Controlled Slip Seconds alarm is
declared.

t1e1CSSCount

ipadt1e1BPVSAlarmDeclared

25015

This trap is sent out when a
Bipolar Violation Seconds alarm
is declared.

t1e1BPVSCount

ipadt1e1OOFSAlarmDeclared

25016

This trap is sent out when an Out
of Frame Seconds alarm is
declared.

t1e1OOFSCount

ipadt1e1AISAlarmExists

25017

This trap is sent out when an
Alarm Indication Signal alarm is
declared.

t1e1AISCount

ipadt1e1RASAlarmExists

25018

This trap is sent out when a
Remote Alarm Signal alarm is
declared.

t1e1RASCount

ipadDLCIremoteSOSAlarm

25019

This trap is sent when the remote
unit for a DLCI senses and
reports an SOS condition.

ipadDLCIremoteEquipActive

ipadDdsLOSSAlarmDeclared

25020

This trap is sent out when a Loss
of Signal Seconds alarm is
declared.

ddsNetLOSCount

ipadDdsOOFSAlarmDeclared

25021

This trap is sent out when an Out
of Frame Seconds alarm is
declared.

ddsNetOOFCount

ipadDdsOOSSAlarmDeclared

25022

This trap is sent out when an Out
of Service Seconds alarm is
declared.

ddsNetOOSCount

ipadDdsFDLSAlarmDeclared

25023

This trap is sent out when a FDL
error Seconds alarm is declared.

ddsNetFDLCount

ipadDdsBPVSAlarmDeclared

25024

This trap is sent out when a
Bipolar Violation Seconds alarm
is declared.

ddsNetBPVCount

ipadDS0HighAlarmDeclared

25025

This trap is sent out when a high
utilization alarm is declared.

ipadDS0ConfigHighUtilCount

ipadDS0LowAlarmDeclared

25026

This trap is sent out when a low
utilization alarm is declared.

ipadDS0ConfigLowUtilAlarm

ipadHDLCRxHighAlarmDeclared

25027

This trap is sent out when a high
Rx utilization alarm is declared.

ipadHDLCConfigRxHighUtil
Count

ipadHDLCRxLowAlarmDeclared

25028

This trap is sent out when a low
Rx utilization alarm is declared.

ipadHDLCConfigRxLow
UtilAlarm